A precise volumetric assessment of maxillary alveolar defects in patients with cleft lip and palate can reduce donor site morbidity or allow accurate preparation of bone substitutes in future applications. However, there is a lack of agreement regarding the optimal volumetric technique to adopt. This study measured the alveolar bone defects by using two cone-beam computed tomography (CBCT)-based surgical simulation methods. Presurgical CBCT scans from 32 patients with unilateral or bilateral clefts undergoing alveolar bone graft surgery were analyzed. Two hands-on CBCT-based volumetric measurement methods were compared: The 3D real-scale printed model-based surgical method and the virtual surgical method. Different densities of CBCT were compared. Intra- and inter-examiner reliability was assessed. For patients with unilateral clefts, the average alveolar defect volumes were 1.09 ± 0.24 and 1.09 ± 0.25 mL (p > 0.05) for 3D printing- and virtual-based models, respectively; for patients with bilateral clefts, they were 2.05 ± 0.22 and 2.02 ± 0.27 mL (p > 0.05), respectively. Bland–Altman analysis revealed that the methods were equivalent for unilateral and bilateral alveolar cleft defect assessment. No significant differences or linear relationships were observed between adjacent different densities of CBCT for model production to obtain the measured volumes. Intra- and inter-examiner reliability was moderate to good (intraclass correlation coeffcient (ICC) > 0.6) for all measurements. This study revealed that the volume of unilateral and bilateral alveolar cleft defects can be equally quantified by 3D-printed and virtual surgical simulation methods and provides alveolar defect-specific volumes which can serve as a reference for planning and execution of alveolar bone graft surgery.

原文英語
文章編號1401
期刊Journal of Clinical Medicine
卷8
發行號9
DOIs
出版品狀態已出版 - 09 2019

文獻附註

Publisher Copyright:
© 2019 by the authors. Licensee MDPI, Basel, Switzerland.

指紋

深入研究「Comparative volume analysis of alveolar defects by 3D simulation」主題。共同形成了獨特的指紋。

引用此