Control and performance identification for small vertical axis wind turbines

W. L. Chen*, Z. C. Li, Y. S. Lin, B. X. Huang

*此作品的通信作者

研究成果: 圖書/報告稿件的類型會議稿件同行評審

7 引文 斯高帕斯(Scopus)

摘要

This paper presents the controller design and a simple method to identify the aerodynamic performance for an installed vertical axis wind turbine (VAWT). The hardware realization of the wind energy conversion system consists of a 1.5kW VAWT-driven permanent magnet synchronous generator (PMSG), a PWM rectifier and a grid-tied PWM inverter. The PWM inverter is mandatory to maintain the dc capacitor voltage mainly adapted for operating in parallel with the power grid. The PWM rectifier, serving as a speed governor, is employed to modulate the revolution speed of the VAWT according to the desired power-speed curve so as to extract maximum power from the wind. To guarantee the aerodynamic performance of the VAWT, a simple method, based on the long-term recorded energy efficiency, can determine the optimum power-speed curve for the VAWT. The effectiveness of the proposed strategy is assessed experimentally by examining the closed-loop system response to various wind speeds.

原文英語
主出版物標題IET Conference on Renewable Power Generation, RPG 2011
頁面P13
版本579 CP
DOIs
出版狀態已出版 - 2011
事件IET Conference on Renewable Power Generation, RPG 2011 - Edinburgh, 英國
持續時間: 09 05 201108 09 2011

出版系列

名字IET Conference Publications
號碼579 CP
2011

Conference

ConferenceIET Conference on Renewable Power Generation, RPG 2011
國家/地區英國
城市Edinburgh
期間09/05/1108/09/11

指紋

深入研究「Control and performance identification for small vertical axis wind turbines」主題。共同形成了獨特的指紋。

引用此