Detection of recurrent nasopharyngeal carcinomas with thallium-201 single-photon emission computed tomography in patients with indeterminate magnetic resonance imaging findings after radiotherapy

Chih Jaan Tai*, Ji An Liang, Shih Neng Yang, Ming Hsui Tsai, Cheng Chieh Lin, Chia Hung Kao

*此作品的通信作者

研究成果: 期刊稿件文章同行評審

13 引文 斯高帕斯(Scopus)

摘要

Background. The aim of this study was to evaluate the usefulness of thallium-201 (Tl-201) single-photon emission CT (SPECT) to detect recurrent nasopharyngeal carcinomas (NPC) when MRI findings are indeterminate. Methods. After radiotherapy, 26 NPC patients with indeterminate MRI findings were included in this study. MRI, Tl-201, and biopsy were performed at least 4 months after radiotherapy and within 1 week. The final results were based on histopathologic findings and clinical follow-up after at least 6 months. Results. For detecting recurrent NPC in indeterminate MRI findings, the sensitivity, specificity, and accuracy of Tl-201 SPECT were 92.3%, 92.3%, and 92.3%, respectively. Conclusions. On the basis of this result, Tl-201 SPECT seems to be effective in detecting recurrent NPC when MRI findings are indeterminate.

原文英語
頁(從 - 到)227-231
頁數5
期刊Head and Neck
25
發行號3
DOIs
出版狀態已出版 - 01 03 2003
對外發佈

指紋

深入研究「Detection of recurrent nasopharyngeal carcinomas with thallium-201 single-photon emission computed tomography in patients with indeterminate magnetic resonance imaging findings after radiotherapy」主題。共同形成了獨特的指紋。

引用此