Determining factors in relation to lymphovascular characteristics and anastomotic configuration in supermicrosurgical lymphaticovenous anastomosis – A retrospective cohort study

  • Po Lun Tsai
  • , Shao Chun Wu
  • , Wei Che Lin
  • , Daisuke Mito
  • , Min Hsien Chiang
  • , Ching Hua Hsieh
  • , Johnson Chia Shen Yang*
  • *此作品的通信作者
  • Chang Gung University
  • The University of Tokyo
  • Xiamen Chang Gung Hospital

研究成果: 期刊稿件 › 文章 › 同儕審查

31 引文 斯高帕斯(Scopus)

摘要

Introduction: Supermicrosurgical lymphaticovenous anastomosis (LVA) can be performed in different configuration such as end-to-end (LVEEA), end-to-side (LVESA), and side-to-end (LVSEA). Each configuration has its own advantages and disadvantages. However, it has remained ambiguous as to which anastomotic o configuration to choose. The aim of this study is to analyze and compare the relative sizes of lymphatic vessel (LV) and recipient vein (RV), in attempts to provide the basis for proper selections of the anastomotic configuration. Methods: From March 2016 to October 2018, 100 lymphedema patients with 103 lymphedematous lower limbs (stage I-III) were included. All patients underwent supermicrosurgical LVA. Demographic data and intraoperative findings, including the number and size of the LV/RV, the size discrepancies, and the numbers of LVA performed were recorded. The severity of LVs were classified based on the lymphosclerosis classification (s0, s1, s2, and s3). One-way ANOVA test and post hoc analysis with Bonferroni's correction were performed for size discrepancy analysis. Results: A total 730 LVA were performed with 621 LVs and 468 RVs, averaging 7.1 LVA per limb. Of these, 367 (50.3%) were LVEEA, 333 (45.6%) were LVESA, and 30 (4.1%) were LVSEA. The average LV and RV size was 0.61 ± 0.35 mm and 0.87 ± 0.43 mm, respectively (p < 0.001). The average LV size in different configuration: LVEEA = LVESA < LVSEA (p < 0.001); The average RV size: LVEEA = LVSEA < LVESA (p < 0.001); The size discrepancy: LVESA > LVSEA > LVEEA (p < 0.001).The LVSEA group has more s1 lymphatic vessels as opposed to LVEEA and LVESA (p = 0.004). Conclusion: The size and the comparative discrepancy between the LVs and RVs are the determining factors for proper anastomotic configuration selection during LVA. LVESA was more frequently performed when vessel size discrepancy was larger. The efficacy of each anastomotic configuration has yet to be determined.

原文英語
頁(從 - 到)39-46
頁數8
期刊International Journal of Surgery
卷81
DOIs
出版品狀態已出版 - 09 2020
對外發佈是

文獻附註

Publisher Copyright:
© 2020 The Author(s)

指紋

深入研究「Determining factors in relation to lymphovascular characteristics and anastomotic configuration in supermicrosurgical lymphaticovenous anastomosis – A retrospective cohort study」主題。共同形成了獨特的指紋。

引用此