T1 - Diagnosis of human metapneumovirus in patients hospitalized with acute lower respiratory tract infection using a metal-enhanced fluorescence technique
AU - Chang, Ying Feng
AU - Tsao, Kuo Chien
AU - Liu, Yi Chun
AU - Chen, Yu Chi
AU - Yu, Pei Chun
AU - Huang, Yhu Chering
AU - Chou, Chien
N1 - Publisher Copyright:
© 2014 Elsevier B.V.
PY - 2015/3/1
Y1 - 2015/3/1
N2 - Human metapneumovirus (hMPV) is a common respiratory tract infection in children. However, conventional immunofluorescence assays (IFAs) for detecting hMPV in respiratory samples have limited reliability with a sensitivity and false-negative predictive value of 58.1% and approximately 17.8%, respectively. In this study, hMPV was measured in 91 clinical respiratory samples (55 sputum and 36 nasopharyngeal aspirate samples), which were obtained from children under three years of age, utilizing our previously developed high-throughput metal-enhanced fluorescence (MEF)-based biosensor (HT-MEFB). The sensitivity of HT-MEFB for hMPV detection in the 91 samples was improved by up to 77.4% compared with that obtained with IFAs, and the specificity of HT-MEFB for hMPV detection was 91.7%. In addition, the specificity and accuracy obtained after the selection of 55 sputum samples as the analyzed specimen reached 92.3% and 90.9%, respectively. Thus, in terms of accuracy, high throughput, and sensitivity, HT-MEFB exhibits considerable potential for hMPV detection in clinical settings.
AB - Human metapneumovirus (hMPV) is a common respiratory tract infection in children. However, conventional immunofluorescence assays (IFAs) for detecting hMPV in respiratory samples have limited reliability with a sensitivity and false-negative predictive value of 58.1% and approximately 17.8%, respectively. In this study, hMPV was measured in 91 clinical respiratory samples (55 sputum and 36 nasopharyngeal aspirate samples), which were obtained from children under three years of age, utilizing our previously developed high-throughput metal-enhanced fluorescence (MEF)-based biosensor (HT-MEFB). The sensitivity of HT-MEFB for hMPV detection in the 91 samples was improved by up to 77.4% compared with that obtained with IFAs, and the specificity of HT-MEFB for hMPV detection was 91.7%. In addition, the specificity and accuracy obtained after the selection of 55 sputum samples as the analyzed specimen reached 92.3% and 90.9%, respectively. Thus, in terms of accuracy, high throughput, and sensitivity, HT-MEFB exhibits considerable potential for hMPV detection in clinical settings.
KW - Gold nanoparticles
KW - High-throughput biosensor
KW - Localized surface plasmon resonance
KW - Metal-enhanced fluorescence
KW - Virus detection
UR - http://www.scopus.com/inward/record.url?scp=84919909619&partnerID=8YFLogxK
U2 - 10.1016/j.jviromet.2014.12.005
DO - 10.1016/j.jviromet.2014.12.005
M3 - 文章
C2 - 25522922
AN - SCOPUS:84919909619
SN - 0166-0934
VL - 213
SP - 151
EP - 156
JO - Journal of Virological Methods
JF - Journal of Virological Methods
ER -