T1 - Effects of heart rate on motion artifacts of the aorta on non-ECG-assisted 0.5-sec thoracic MDCT
AU - Ko, Sheung Fat
AU - Hsieh, Ming Jeng
AU - Chen, Min Chi
AU - Ng, Shu Hang
AU - Fang, Fu-Min
AU - Huang, Chung Cheng
AU - Wan, Yung Liang
AU - Lee, Tze Yu
PY - 2005
Y1 - 2005
N2 - OBJECTIVE. Our aim was to evaluate the effects of heart rate on aortic motion artifacts on 0.5-sec non-ECG-assisted thoracic MDCT. MATERIALS AND METHODS. A total of 124 non-ECG-assisted thoracic MDCT scans with satisfactory simultaneous ECG data were reviewed. Scans were grouped according to patient heart rates (beats per minute [bpm]: group A, 46-55; B, 56-65; C, 66-75; D, 76-85; E, 86-95; and F > 95). The groups were compared regarding the presence, locations, and spatial distributions of pulsation artifact, number of slices affected, maximum amplitude of pulsation, continuity of artifact, and the presence of superior vena cava (SVC) pseudoflaps. RESULTS. Of the 124 scans, 114 (91.9%) had aortic motion artifacts, with prevalence ranging from 85.3% (66-75 bpm) to 100% (65 bpm or less). Of the 114 motion artifacts, all affected the ascending aorta, 105 (92.1%) involved the left anterior and right posterior aspects of the aortic circumference, and 106 (93%) were associated with SVC pseudoflaps. Group B had significantly greater numbers of images with artifacts (p < 0.001-0.006), greater artifact amplitudes (p < 0.001-0.002), and a higher continuity trend for the artifacts (p = 0.003-0.194) than did the other five groups. CONCLUSION. Aortic motion artifacts are frequently seen on thoracic MDCT, especially in patients with heart rates of 65 bpm or less. The presence of a SVC pseudoflap is helpful for distinguishing artifacts from dissection. If aortic disease is suspected, then measures to reduce motion artifact, such as ECG-gating, should be considered.
AB - OBJECTIVE. Our aim was to evaluate the effects of heart rate on aortic motion artifacts on 0.5-sec non-ECG-assisted thoracic MDCT. MATERIALS AND METHODS. A total of 124 non-ECG-assisted thoracic MDCT scans with satisfactory simultaneous ECG data were reviewed. Scans were grouped according to patient heart rates (beats per minute [bpm]: group A, 46-55; B, 56-65; C, 66-75; D, 76-85; E, 86-95; and F > 95). The groups were compared regarding the presence, locations, and spatial distributions of pulsation artifact, number of slices affected, maximum amplitude of pulsation, continuity of artifact, and the presence of superior vena cava (SVC) pseudoflaps. RESULTS. Of the 124 scans, 114 (91.9%) had aortic motion artifacts, with prevalence ranging from 85.3% (66-75 bpm) to 100% (65 bpm or less). Of the 114 motion artifacts, all affected the ascending aorta, 105 (92.1%) involved the left anterior and right posterior aspects of the aortic circumference, and 106 (93%) were associated with SVC pseudoflaps. Group B had significantly greater numbers of images with artifacts (p < 0.001-0.006), greater artifact amplitudes (p < 0.001-0.002), and a higher continuity trend for the artifacts (p = 0.003-0.194) than did the other five groups. CONCLUSION. Aortic motion artifacts are frequently seen on thoracic MDCT, especially in patients with heart rates of 65 bpm or less. The presence of a SVC pseudoflap is helpful for distinguishing artifacts from dissection. If aortic disease is suspected, then measures to reduce motion artifact, such as ECG-gating, should be considered.
UR - https://www.scopus.com/pages/publications/18244402924
U2 - 10.2214/ajr.184.4.01841225
DO - 10.2214/ajr.184.4.01841225
M3 - 文献综述
C2 - 15788600
AN - SCOPUS:18244402924
SN - 0361-803X
VL - 184
SP - 1225
EP - 1230
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 4
ER -