Effects of pressure control device (Sensawake™) on obstructive sleep apnea (osa) patients who remove the mask for unknown reasons during automatic continuous positive airway pressure (auto-cpap) therapy: A prospective randomized crossover trial

  • Chang Gung Memorial Hospital
  • Chang Gung University

研究成果: 期刊稿件 › 文章 › 同儕審查

摘要

Background and Objectives: Obstructive sleep apnea (OSA) patients may remove their mask unconsciously during automatic continuous positive airway pressure (Auto-CPAP) therapy and therefore cannot receive good treatment. The discomfort from the airflow of Auto-CPAP may be one reason for interrupted sleep. Sens Awake (SA) can detect the arousal and lower the pressure to prevent patients from fully awakening from sleep. Materials and Methods: To evaluate the effect of SA, we designed a prospective, randomized, crossover trial comparing Auto-CPAP with and without SA on Epworth Sleepiness Scale (ESS), Pittsburgh Sleep Quality Index (PSQI), Nasal Obstruction Symptom Evaluation (NOSE) Scale and recorded data from the auto-CPAP machine. Results: In the 25 patients who completed the study, the gender, age, body mass index, neck circumference, polysomnography data, and previous CPAP use were not significantly different between the two arms. The average and 90th percentile pressures were significantly lower during SA on (SA on vs. off: 6.9 ± 2.7 vs. 7.3 ± 2.6 [p = 0.032] and 8.6 ± 3.0 vs. 9.2 ± 2.9 [p = 0.002], respectively). The time used, days used, compliance, average and 90th percentile leaks, and the residual Apnea-Hypopnea Index (AHI) were not significantly changed between the SA on-and-off. Based on the subjective evaluation, PSQI, ESS, and NOSE were not significantly different between the SA on-and-off; however, based on additional analyses which were compared with baseline data, the ESS was significantly lower when the SA was on (SA on vs. baseline: 11.1 ± 6.1 vs. 13.2 ± 6.0 [p = 0.023]). Conclusions: CPAP therapy with or without two weeks of the SA had a similar effect on CPAP use, sleep quality, daytime sleepiness, and nasal obstruction. The SA may have a tendency to improve daytime sleepiness, but needs further study with a longer duration of treatment.

原文英語
文章編號915
期刊Medicina (Lithuania)
卷57
發行號9
DOIs
出版品狀態已出版 - 09 2021

文獻附註

Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.

指紋

深入研究「Effects of pressure control device (Sensawake™) on obstructive sleep apnea (osa) patients who remove the mask for unknown reasons during automatic continuous positive airway pressure (auto-cpap) therapy: A prospective randomized crossover trial」主題。共同形成了獨特的指紋。

引用此