跳至主導覽 跳至搜尋 跳過主要內容

Efficient simulation of voxelized phantom in GATE with embedded SimSET multiple photon history generator

  • Hsin Hon Lin*
  • , Keh Shih Chuang
  • , Yi Hsing Lin
  • , Yu Ching Ni
  • , Jay Wu
  • , Meei Ling Jan
  • *此作品的通信作者
  • National Tsing Hua University
  • Taiwan Power Company
  • Atomic Energy Council, Taiwan
  • China Medical University Taichung

研究成果: 期刊稿件 › 文章 › 同儕審查

17 引文 斯高帕斯(Scopus)

摘要

GEANT4 Application for Tomographic Emission (GATE) is a powerful Monte Carlo simulator that combines the advantages of the general-purpose GEANT4 simulation code and the specific software tool implementations dedicated to emission tomography. However, the detailed physical modelling of GEANT4 is highly computationally demanding, especially when tracking particles through voxelized phantoms. To circumvent the relatively slow simulation of voxelized phantoms in GATE, another efficient Monte Carlo code can be used to simulate photon interactions and transport inside a voxelized phantom. The simulation system for emission tomography (SimSET), a dedicated Monte Carlo code for PET/SPECT systems, is well-known for its efficiency in simulation of voxel-based objects. An efficient Monte Carlo workflow integrating GATE and SimSET for simulating pinhole SPECT has been proposed to improve voxelized phantom simulation. Although the workflow achieves a desirable increase in speed, it sacrifices the ability to simulate decaying radioactive sources such as non-pure positron emitters or multiple emission isotopes with complex decay schemes and lacks the modelling of time-dependent processes due to the inherent limitations of the SimSET photon history generator (PHG). Moreover, a large volume of disk storage is needed to store the huge temporal photon history file produced by SimSET that must be transported to GATE. In this work, we developed a multiple photon emission history generator (MPHG) based on SimSET/PHG to support a majority of the medically important positron emitters. We incorporated the new generator codes inside GATE to improve the simulation efficiency of voxelized phantoms in GATE, while eliminating the need for the temporal photon history file. The validation of this new code based on a MicroPET R4 system was conducted for 124I and 18F with mouse-like and rat-like phantoms. Comparison of GATE/MPHG with GATE/GEANT4 indicated there is a slight difference in energy spectra for energy below 50 keV due to the lack of x-ray simulation from 124I decay in the new code. The spatial resolution, scatter fraction and count rate performance are in good agreement between the two codes. For the case studies of 18F-NaF (124I-IAZG) using MOBY phantom with 1 × 1 × 1 mm3voxel sizes, the results show that GATE/MPHG can achieve acceleration factors of approximately 3.1 × (4.5 ×), 6.5 × (10.7 ×) and 9.5 × (31.0 ×) compared with GATE using the regular navigation method, the compressed voxel method and the parameterized tracking technique, respectively. In conclusion, the implementation of MPHG in GATE allows for improved efficiency of voxelized phantom simulations and is suitable for studying clinical and preclinical imaging.

原文英語
頁(從 - 到)6231-6250
頁數20
期刊Physics in Medicine and Biology
卷59
發行號20
DOIs
出版品狀態已出版 - 21 10 2014
對外發佈是

文獻附註

Publisher Copyright:
© 2014 Institute of Physics and Engineering in Medicine.

指紋

深入研究「Efficient simulation of voxelized phantom in GATE with embedded SimSET multiple photon history generator」主題。共同形成了獨特的指紋。

引用此