跳至主導覽 跳至搜尋 跳過主要內容

Exploring the Location of Corneal Pigmented Arc and Myopia Control Efficacy in Orthokeratology-Treated Children Using Pentacam Measurements

  • Yu Kai Kuo
  • , Lan Hsin Chuang
  • , Chi Chun Lai
  • , Pei Chang Wu
  • , Shin Yi Chen
  • , Hung Chi Chen
  • , Ling Yeung
  • , Nan Kai Wang
  • , Yih Shiou Hwang
  • , Chun Fu Liu*
  • *此作品的通信作者
  • Chang Gung Memorial Hospital
  • Taiwan Myopia Disease Society
  • Chang Gung University
  • Columbia University
  • Xiamen Chang Gung Hospital
  • Taipei City Hospital
  • National Yang Ming Chiao Tung University

研究成果: 期刊稿件文章同行評審

2 引文 斯高帕斯(Scopus)

摘要

OBJECTIVES: To determine the location and intensity of the corneal pigmented arc in orthokeratology (ortho-k)-treated children and its relationship with annual axial length (AL) change using Pentacam.

METHODS: This retrospective cohort study enrolled children aged 9 to 15 years who had been followed up for at least one year after ortho-k treatment for myopia control. A Pentacam was used to determine the location and intensity of pigmented arc after lens wear. Annual AL changes were further used as the outcome measurement to determine their relationships with the location and intensity of pigmented arc using generalized estimating equations (GEE).

RESULTS: In total, 62 eyes from 33 patients (mean age 10.9 years) were included in our final analysis. The mean follow-up time was 30.6 months. The mean annual AL changes were 0.10 mm. Age statistically correlated with annual AL change (GEE, P= 0.033). In addition, the annual AL change was negatively associated with the relative vertical distance of the lowest density of pigmented arc point based on the visual center, pupil center, and corneal thinnest point after adjustment with age ( P =0.005, P =0.004, and P< 0.001, respectively).

CONCLUSIONS: Pentacam could be a useful tool for evaluating the location and intensity of the corneal pigmented arc. In addition, there was a negative correlation between the vertical distance of the pigmented arc and annual AL change. These findings may provide important information regarding myopia control, next-generation ortho-k design, and prescription.

原文英語
頁(從 - 到)84-90
頁數7
期刊Eye and Contact Lens
50
發行號2
DOIs
出版狀態已出版 - 01 02 2024
對外發佈

文獻附註

Copyright © 2024 Contact Lens Association of Ophthalmologists.

指紋

深入研究「Exploring the Location of Corneal Pigmented Arc and Myopia Control Efficacy in Orthokeratology-Treated Children Using Pentacam Measurements」主題。共同形成了獨特的指紋。

引用此