Incidence and risk factors of guidewire-induced arrhythmia during internal jugular venous catheterization: Comparison of marked and plain J- wires

Tak Yu Lee, Chun Sung Sung, Ya Chuan Chu, Jiin Tarng Liou, Ping Wing Lui*

*此作品的通信作者

研究成果: 期刊稿件文章同行評審

32 引文 斯高帕斯(Scopus)

摘要

Study Objectives: To compare the incidence and risk factors of guidewire-induced arrhythmia (GIA) during internal jugular venous catheterization (IJV). Design: Prospective study. Setting: Operating rooms at a medical center. Patients: 303 ASA physical status I, II, III, and IV patients undergoing elective surgery. Interventions: All patients were cannulated with the central venous catheters placed via the right internal jugular vein after induction of anesthesia. They were randomly divided into two groups. In one group, we used a marked J-wire and inserted up to, but not beyond 20 cm (Group M, n = 127). In the other group, a plain unmarked J-wire was used and inserted at will (Group UM, n = 176). All IJV catheterizations were performed by residents, and the length of J-wire inserted was then measured. Measurements and Main Results: Types of arrhythmia [eg, premature atrial contraction (PAC) or premature ventricular contraction (PVC)] were interpreted by attending anesthesiologists on lead II ECG. Patients in Group UM had a significantly greater incidence of GIA than those in Group M (28.4% vs. 3.9%; p < .005). However, in both groups, PAC occurred more frequently than PVC. Factors such as the inserted length of guidewire longer than 20 cm, body height less than 170 cm, and female gender were significantly associated with GIA (p < 0.005). Conclusions: Limiting the length of the guidewire insertion to less than or equal to 20 cm for right IJV catheterization by using a marked J-wire will reduce the incidence of GIA. We recommend the use of a marked J-wire for IJV catheterization.

原文英語
頁(從 - 到)348-351
頁數4
期刊Journal of Clinical Anesthesia
8
發行號5
DOIs
出版狀態已出版 - 08 1996
對外發佈

指紋

深入研究「Incidence and risk factors of guidewire-induced arrhythmia during internal jugular venous catheterization: Comparison of marked and plain J- wires」主題。共同形成了獨特的指紋。

引用此