跳至主導覽 跳至搜尋 跳過主要內容

Integrating CAD and 3D-printing techniques to construct an in vitro laser standard treatment platform for evaluating the effectiveness of sterilization by Er: YAG laser in peri-implant intra-bony defects

  • Shih Hao Chang
  • , Hsiang I. Mei
  • , Chun Li Lin*
  • *此作品的通信作者
  • Chang Gung Memorial Hospital
  • Chang Gung University
  • National Yang Ming Chiao Tung University

研究成果: 期刊稿件文章同行評審

1 引文 斯高帕斯(Scopus)

摘要

This study established an in vitro model mimicking clinical peri-implant intra-bony defects. We investigated the effect of access limitation and the bactericidal effectiveness of erbium-doped yttrium, aluminum and garnet (Er:YAG) laser irradiation in shallow and deep peri-implant defects at different tooth positions. Reverse engineering, computer-aided design (CAD), and 3D-printing techniques were integrated to establish physical peri-implant intra-bony defect models at mandibular central incisor, first premolar, and first molar positions with shallow (2 mm depth) or deep (6 mm depth) defects and with 1.5 mm and 1.8 mm widths at the bottom and crestal portions of the alveolar process, respectively. Three-dimensional printed suites at the corresponding implant sites replaced experimental implant specimens for the investigation of bacterial adhesion in individuals. Dental implants with diameters of 3, 4 and 5 mm were utilized at the mandibular incisor, premolar, and molar positions, respectively. Bacterial adhesion of Gram (-) Escherichia coli on the exposed implant surfaces prior to sterilization was assessed. Sterilization with shallow and deep intra-bony defects was investigated by measuring the reduction of residual viable bacteria on implants after 60 s of irradiation with an Er:YAG laser. The adhesion rate of Gram (-) Escherichia coli on the investigated implant surfaces ranged from 1% to 3% (1.76 ± 1.25%, 2.19 ± 0.75% and 2.66 ± 1.26% for 3, 4, and 5 mm implants, respectively). With shallow peri-implant bony defects, the Er:YAG laser sterilization rates were 99.6 ± 0.5%, 99.3 ± 0.41% and 93.8 ± 7.65% at mandibular incisor, premolar, and molar positions, respectively. Similarly, sterilization rates in deep peri-implant defects were 99 ± 1.35%, 99.1 ± 0.98% and 97.14 ± 2.57%, respectively. A 3D-printed model with replaceable implant specimens mimicking human peri-implant intra-bony defects was established and tested in vitro. This investigation demonstrated effective sterilization using Er:YAG laser irradiation in both shallow and deep peri-implant intra-bony defects at different positions and diameters of dental implants.

原文英語
文章編號3431
期刊Applied Sciences (Switzerland)
10
發行號10
DOIs
出版狀態已出版 - 01 05 2020
對外發佈

文獻附註

Publisher Copyright:
© 2020 by the authors.

指紋

深入研究「Integrating CAD and 3D-printing techniques to construct an in vitro laser standard treatment platform for evaluating the effectiveness of sterilization by Er: YAG laser in peri-implant intra-bony defects」主題。共同形成了獨特的指紋。

引用此