跳至主導覽 跳至搜尋 跳過主要內容

Investigation of Electrocatalysis for Electrical Field-Based Anti-Interference Histamine Biosensor With Readout Circuit

  • Wei Cheng Lin*
  • , Tzu Wei Chung
  • , Yi Huan Chang
  • , Bing Hong Chen
  • , Wei Lun Yen
  • *此作品的通信作者
  • Chang Gung University
  • Chang Gung Memorial Hospital

研究成果: 期刊稿件 › 文章 › 同行評審

摘要

This work introduces an electrical field-based biosensor for accurate quantification of histamine, featuring a polyvinyl chloride (PVC) membrane. The device employs a highly sensitive analog front-end circuit with an 8- \mu V low-drift voltage offset, enabling detection over a wide concentration range of 0.02–100 \mu M, achieving a sensitivity of 12.35 mV/ \mu M. When exposed to histamine in the presence of diamine oxidase (DAO), the sensor exhibited a pronounced signal change of 63%. Marked signal suppression occurs exclusively under severe interference conditions, specifically when the concentration ratio of histamine to putrescine, cadaverine, and tyramine reaches 1:20. Owing to its excellent sensitivity and selectivity, the proposed histamine biosensor is well-suited for rapid, on-site histamine detection in food and fish markets, offering strong potential for food safety monitoring applications.

原文英語
頁(從 - 到)12704-12711
頁數8
期刊IEEE Sensors Journal
卷26
發行號8
DOIs
出版狀態已出版 - 15 04 2026
對外發佈是

文獻附註

Publisher Copyright:
© 2001-2012 IEEE.

指紋

深入研究「Investigation of Electrocatalysis for Electrical Field-Based Anti-Interference Histamine Biosensor With Readout Circuit」主題。共同形成了獨特的指紋。

引用此