Measuring Anisotropic Diffusion in Kidney Using MRI

  • Chang Gung Memorial Hospital
  • Chang Gung University

研究成果: 期刊稿件 › 文章 › 同儕審查

11 引文 斯高帕斯(Scopus)

摘要

Rationale and Objectives: To measure the anisotropic diffusion in kidney and to demonstrate the feasibility of renal tractography. Materials and Methods: Diffusion tensor imaging was acquired in kidney from 10 healthy volunteers and 5 patients with chronic kidney disease. Diffusion indices were calculated from the tensor, including fractional anisotropy, intervoxel diffusion coherence, and mean/axial/radial diffusivity. Results: Acquisitions with respiratory triggering could provide improved image quality in all diffusion indices, as compared to that by breathhold. It is sufficient to use five to seven scan averages when the measured diffusion indices converge to a steady state in medulla, which reduced the acquisition time in a triggered measurement down to a clinically tolerable limit. Second, the measured diffusion indices can be affected by the diffusion weighting. An increased diffusion weighting will lead to an underestimation in all diffusion indices. Finally the direction of water diffusion is consistent in the kidney cortex, which was properly reflected in intervoxel diffusion coherence. In a feasibility study in healthy volunteers and patients, renal tractography was performed that visualized the organized renal structure and as it declined with the progress of chronic kidney disease. Conclusion: When compared to conventional breath hold technique, the significant improvement in image quality compensated for the prolonged acquisition time. Therefore, triggered acquisition is preferred in a clinical setting because it required less from patient cooperation.

原文英語
頁(從 - 到)1168-1174
頁數7
期刊Academic Radiology
卷18
發行號9
DOIs
出版品狀態已出版 - 09 2011

UN SDG

此研究成果有助於以下永續發展目標

  1. SDG3 健康與福祉
    SDG3 健康與福祉

指紋

深入研究「Measuring Anisotropic Diffusion in Kidney Using MRI」主題。共同形成了獨特的指紋。

引用此