摘要
Parallel connections of three-phase Vienna rectifiers are commonly used to increase the power ratings of electric vehicle charging stations in recent years. However, parallel operation can create a path for zero sequence circulating current (ZSCC), particularly when the rectifiers are operating under interleaved modes with unbalanced filter inductors. To tackle out this issue, an integrated control scheme is proposed in this article. Based on these frequency components of the ZSCC, the proposed control scheme has two layers. The low frequency component of the ZSCC is mitigated by using PIR control in the inner current control loop under the rotational reference frame, while the high frequency component of the ZSCC is reduced by applying the Discontinuous Pulse Width Modulation (DPWM) technique with proper zero sequence injections. The effectiveness of the proposed control scheme is validated through both numerical simulations and hardware experiments.
| 原文 | 英語 |
|---|---|
| 頁(從 - 到) | 5804-5817 |
| 頁數 | 14 |
| 期刊 | IEEE Transactions on Industry Applications |
| 卷 | 59 |
| 發行號 | 5 |
| DOIs | |
| 出版品狀態 | 已出版 - 01 09 2023 |
| 對外發佈 | 是 |
文獻附註
Publisher Copyright:© 1972-2012 IEEE.
UN SDG
此研究成果有助於以下永續發展目標
-
SDG7 可負擔能源
指紋
深入研究「Mitigating Circulating Currents of Parallel Three-Phase Vienna Rectifiers with Unbalanced Filter Inductors」主題。共同形成了獨特的指紋。引用此