Multiple energy X-ray imaging of metal oxide particles inside gingival tissues

  • Jarrod Cortez
  • , Ignacio Romero
  • , Jason Ngo
  • , Md Sayed Tanveer Azam
  • , Chuang Niu
  • , Cássio Luiz Coutinho Almeida-Da-Silva
  • , Leticia Ferreira Cabido
  • , David M. Ojcius
  • , Wei Chun Chin
  • , Ge Wang
  • , Changqing Li*
  • *此作品的通信作者
  • University of California Merced
  • Rensselaer Polytechnic Institute
  • University of the Pacific

研究成果: 期刊稿件 › 文章 › 同行評審

2 引文 斯高帕斯(Scopus)

摘要

BACKGROUND: Periodontal disease affects over 50% of the global population and is characterized by gingivitis as the initial sign. One dental health issue that may contribute to the development of periodontal disease is foreign body gingivitis (FBG), which can result from exposure to some kinds of foreign metal particles from dental products or food. OBJECTIVE: We design a novel, portable, affordable, multispectral X-ray and fluorescence optical microscopic imaging system dedicated to detecting and differentiating metal oxide particles in dental pathological tissues. A novel denoising algorithm is applied. We verify the feasibility and optimize the performance of the imaging system with numerical simulations. METHODS: The designed imaging system has a focused X-ray tube with tunable energy spectra and thin scintillator coupled with an optical microscope as detector. A simulated soft tissue phantom is embedded with 2-micron thick metal oxide discs as the imaged object. GATE software is used to optimize the systematic parameters such as energy bandwidth and X-ray photon number. We have also applied a novel denoising method, Noise2Sim with a two-layer UNet structure, to improve the simulated image quality. RESULTS: The use of an X-ray source operating with an energy bandwidth of 5keV, X-ray photon number of 108, and an X-ray detector with a 0.5 micrometer pixel size in a 100 by 100-pixel array allowed for the detection of particles as small as 0.5 micrometer. With the Noise2Sim algorithm, the CNR has improved substantially. A typical example is that the Aluminum (Al) target's CNR is improved from 6.78 to 9.72 for the case of 108 X-ray photons with the Chromium (Cr) source of 5keV bandwidth. CONCLUSIONS: Different metal oxide particles were differentiated using Contrast-To-Noise ratio (CNR) by utilizing four different X-ray spectra.

原文英語
頁(從 - 到)87-103
頁數17
期刊Journal of X-Ray Science and Technology
卷32
發行號1
DOIs
出版狀態已出版 - 02 02 2024
對外發佈是

文獻附註

Publisher Copyright:
© 2024-IOS Press. All rights reserved.

指紋

深入研究「Multiple energy X-ray imaging of metal oxide particles inside gingival tissues」主題。共同形成了獨特的指紋。

引用此