TY - JOUR
T1 - Non-enzymatic electrochemical detection of caffeic acid in food samples with spinel magnesium cobalt oxide incorporated graphene nanohybrid electrocatalyst
AU - Priya, Thangavelu Sakthi
AU - Nataraj, Nandini
AU - Chen, Tse Wei
AU - Chen, Shen Ming
AU - Tamilalagan, Elayappan
AU - Lou, Bih Show
AU - Al-Mohaimeed, Amal M.
AU - Binobead, Manal Abdulaziz
AU - Elshikh, Mohamed S.
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2024/10/15
Y1 - 2024/10/15
N2 - Caffeic acid (CA) is one of the significant polyphenolic compounds primarily used as an antioxidant and medicine. The extensive usage of CA increases toxicity and affects health. Consequently, we have prepared an electrochemical sensor based on spinel magnesium cobalt oxide (MCO) with graphene (GR) sheets derived electrocatalyst (MCO/GR) for the rapid detection of CA. The elemental, and structural details were investigated with several spectroscopic techniques. The electrocatalytic behavior towards the CA was estimated with different voltammetric methods. Our MCO/GR-based electrochemical sensor demonstrated a low detection limit (0.003 µM), optimal sensitivity (1.494 µA µM–1 cm–2), low limit of quantification (0.013 µM), and good linear ranges (0.01 µM to 0.69 µM and 0.69 µM to 447.19 µM). This sensor showed good electrochemical performance and was applied to monitor CA in various food samples and obtained remarkable recoveries. Based on these results, our MCO/GR sensor is a promising electrochemical platform for determining CA.
AB - Caffeic acid (CA) is one of the significant polyphenolic compounds primarily used as an antioxidant and medicine. The extensive usage of CA increases toxicity and affects health. Consequently, we have prepared an electrochemical sensor based on spinel magnesium cobalt oxide (MCO) with graphene (GR) sheets derived electrocatalyst (MCO/GR) for the rapid detection of CA. The elemental, and structural details were investigated with several spectroscopic techniques. The electrocatalytic behavior towards the CA was estimated with different voltammetric methods. Our MCO/GR-based electrochemical sensor demonstrated a low detection limit (0.003 µM), optimal sensitivity (1.494 µA µM–1 cm–2), low limit of quantification (0.013 µM), and good linear ranges (0.01 µM to 0.69 µM and 0.69 µM to 447.19 µM). This sensor showed good electrochemical performance and was applied to monitor CA in various food samples and obtained remarkable recoveries. Based on these results, our MCO/GR sensor is a promising electrochemical platform for determining CA.
KW - Carbon sheets
KW - Electrochemical detection
KW - Food samples
KW - Polyphenol compound
KW - Spinel binary metal oxide
UR - https://www.scopus.com/pages/publications/85197351202
U2 - 10.1016/j.jallcom.2024.175335
DO - 10.1016/j.jallcom.2024.175335
M3 - 文章
AN - SCOPUS:85197351202
SN - 0925-8388
VL - 1002
JO - Journal of Alloys and Compounds
JF - Journal of Alloys and Compounds
M1 - 175335
ER -