跳至主導覽 跳至搜尋 跳過主要內容

Novel Measurement System for Linear Array Type UVC Germicidal System

  • Tal Ping Sun
  • , Chung Ta Huang
  • , Ping Wing Lui
  • , Yi Tai Chen
  • , Hsiu Li Shieh
  • Nan Kai University of Technology
  • National Chi Nan University
  • Veterans General Hospital-Taichung Taiwan

研究成果: 圖書/報告稿件的類型 › 會議稿件 › 同行評審

6 引文 斯高帕斯(Scopus)

摘要

The germicidal system is constructed using a UVC LED illumination module with a wavelength of 275 nm and a power of 1.8 mw. UVC LED has a smaller volume without heat radiation and pollution that meets the requirements of green energy and environmental protection. It is very suitable for sterilization and purification. It can destroy microbiological organisms such as bacteria, viruses, or spores, etc., of their molecular structure of DNA (deoxyribonucleic acid) and RNA (ribonucleic acid) in pathogen cells, which causes the cells to lose the ability to replicate and regenerate, thereby achieving germicidal efficacy. The UVC Germicidal System (abbreviated as UVCGS) is designed with an array of UVC LEDs. The key technologies of the UVCGSs' drive circuit is a new automatic power control system (APC) design, which can make UVC LED in constant current mode and stable electric power for operation. That is, when the power of the UVC LED changes with temperature, the current amount can be automatically adjusted by the driving circuit. So that the UVC LED can be maintained at a different temperature and still keep a stable optical power output to achieve temperature compensation purpose. The design of the drive circuit confirms that the UVCGS being operated at different temperature changes from 0 °C 35 °C and with stable current and stable optical power output capability can sterilize Escherichia coli, Staphylococcus aureus, Acinetobacter baumannii, etc., achieving multiple germicidal benefits. Among them, Acinetobacter baumannii has been experimentally analyzed that within 2-20 seconds of irradiation time, under the condition of average sterilization residual amount at different heights, the proper bactericidal residual amount is about 12-13 (lethal rate is 91-92%, \text{UVGI}=12), and the required minimum germicidal irradiation power dose is 1500\mu \text{W}- Sec/cm2, which meets UVGI standard values and typical lethality standards.

原文英語
主出版物標題Proceedings of 2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019
編輯Teen-Hang Meen
發行者Institute of Electrical and Electronics Engineers Inc.
頁面57-60
頁數4
ISBN(電子)9781728107639
DOIs
出版狀態已出版 - 05 2019
對外發佈是
事件2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019 - Okinawa, 日本
持續時間: 31 05 2019 → 03 06 2019

出版系列

名字Proceedings of 2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019

Conference

Conference2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019
國家/地區日本
城市Okinawa
期間31/05/19 → 03/06/19

文獻附註

Publisher Copyright:
© 2019 IEEE.

UN SDG

此研究成果有助於以下永續發展目標

  1. SDG7 可負擔能源
    SDG7 可負擔能源

指紋

深入研究「Novel Measurement System for Linear Array Type UVC Germicidal System」主題。共同形成了獨特的指紋。

引用此