跳至主導覽 跳至搜尋 跳過主要內容

Oxygen-sensitive T2* magnetic resonance imaging to correlate heart function and ischemic etiology of post-hospitalized chronic heart failure patients

  • Yu Hsiang Juan
  • , Pei Ching Huang
  • , Gigin Lin
  • , Min Hui Liu
  • , Yu Ching Lin
  • , Jiun Jie Wang
  • , Koon Kwan Ng
  • , Yun Chung Cheung
  • , Chao Hung Wang
  • , Shu Hang Ng*
  • *此作品的通信作者
  • Chang Gung University
  • Chang Gung Memorial Hospital
  • National Yang Ming Chiao Tung University

研究成果: 期刊稿件 › 文章 › 同儕審查

2 引文 斯高帕斯(Scopus)

摘要

Purpose: Myocardial oxygenation imaging is a field-of-interest but its clinical utility largely unexplored. We aimed to investigate the myocardial oxygenation status via T2* imaging and compared with the left ventricular ejection fraction (LVEF) in chronic heart failure (HF) patients after hospitalization. Also, we sought to compare the differences in myocardial oxygenation status among patients with ischemic HF, non-ischemic HF and controls. Methods: We prospectively enrolled 60 participants, comprising 20 HF patients with LVEF ≥ 50 % as the improved ejection fraction (HFIEF) group, 20 H F patients with ejection fraction <50 % as the reduced ejection fraction (HFREF) group, and 20 controls. Patients were also dichotomized into ischemic and non-ischemic subgroups. T2* values were compared across the study groups, and correlated with LVEF, myocardial scar distribution and quantity. Results: T2* values positively correlated with LVEF and were significantly lower in the HFREF group as compared with both HFIEF and controls (20.06 vs. 24.23; 20.06 vs. 26.32, respectively, both p < 0.05). Lower T2* values were observed in the HFREF group than the HFIEF group and the ischemic subgroup than the non-ischemic subgroup. No significant correlation existed between T2* value and the myocardial scar amounts in ischemic territory. Conclusions: Oxygen-sensitive T2* measurements showed correlation with LVEF and ischemic etiology in chronic heart failure patients, while the ischemic HFREF patients appeared to be more vulnerable to myocardial oxygen reduction than other groups. T2* measurements may be clinically feasible in monitoring heart failure via myocardial oxygenation and lay the foundation for future studies in prediction heart failure recovery.

原文英語
文章編號109036
期刊European Journal of Radiology
卷128
DOIs
出版品狀態已出版 - 07 2020

文獻附註

Publisher Copyright:
© 2020 Elsevier B.V.

UN SDG

此研究成果有助於以下永續發展目標

  1. SDG3 健康與福祉
    SDG3 健康與福祉

指紋

深入研究「Oxygen-sensitive T2* magnetic resonance imaging to correlate heart function and ischemic etiology of post-hospitalized chronic heart failure patients」主題。共同形成了獨特的指紋。

引用此