Potential risk for bacterial contamination in conventional reused ventilator systems and disposable closed ventilator-suction systems

Ya Chi Li, Hui Ling Lin, Fang Chun Liao, Sing Siang Wang, Hsiu Chu Chang, Hung Fu Hsu, Sue Hsien Chen, Gwo Hwa Wan

研究成果: 期刊稿件文章同行評審

14 引文 斯高帕斯(Scopus)

摘要

Background Few studies have investigated the difference in bacterial contamination between conventional reused ventilator systems and disposable closed ventilator-suction systems. The aim of this study was to investigate the bacterial contamination rates of the reused and disposable ventilator systems, and the association between system disconnection and bacterial contamination of ventilator systems. Methods The enrolled intubated and mechanically ventilated patients used a conventional reused ventilator system and a disposable closed ventilator-suction system, respectively, for a week; specimens were then collected from the ventilator circuit systems to evaluate human and environmental bacterial contamination. The sputum specimens from patients were also analyzed in this study. Results The detection rate of bacteria in the conventional reused ventilator system was substantially higher than that in the disposable ventilator system. The inspiratory and expiratory limbs of the disposable closed ventilator-suction system had higher bacterial concentrations than the conventional reused ventilator system. The bacterial concentration in the heated humidifier of the reused ventilator system was significantly higher than that in the disposable ventilator system. Positive associations existed among the bacterial concentrations at different locations in the reused and disposable ventilator systems, respectively. The predominant bacteria identified in the reused and disposable ventilator systems included Acinetobacter spp., Bacillus cereus, Elizabethkingia spp., Pseudomonas spp., and Stenotrophomonas (Xan) maltophilia. Conclusions Both the reused and disposable ventilator systems had high bacterial contamination rates after one week of use. Disconnection of the ventilator systems should be avoided during system operation to decrease the risks of environmental pollution and human exposure, especially for the disposable ventilator system.

原文英語
文章編號0194246
期刊PLoS ONE
13
發行號3
DOIs
出版狀態已出版 - 03 2018

文獻附註

Publisher Copyright:
© 2018 Li et al. This is an open ccess article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and eproduction in any medium, provided the original author and source are credited.

指紋

深入研究「Potential risk for bacterial contamination in conventional reused ventilator systems and disposable closed ventilator-suction systems」主題。共同形成了獨特的指紋。

引用此