Prediction and discrimination of skeletal muscle function by bioelectrical impedance vector analysis using a standing impedance analyzer in healthy Taiwanese adults

  • Li Wen Lee
  • , Hsueh Kuan Lu
  • , Yu Yawn Chen
  • , Chung Liang Lai
  • , Lee Ping Chu
  • , Meng Che Hsieh
  • , Kuen Chang Hsieh*
  • *此作品的通信作者
  • National Taiwan University of Sport
  • National Taitung Junior College
  • Ministry of Health and Welfare
  • Asia University Taiwan
  • China Medical University Taichung
  • Charder Electronic Co., Ltd
  • National Chin-Yi University of Technology Taiwan

研究成果: 期刊稿件 › 文章 › 同儕審查

4 引文 斯高帕斯(Scopus)

摘要

Background Bioelectrical impedance vector analysis (BIVA) has been used for prediction of muscle performance. However, little is known about BIVA in Asian adults, and even less is known about using standing BIVA devices. Standing impedance analyzer allows quicker and more convenient way to gather data than conventional supine analyzer and is more suitable for clinical practice. This study aimed to investigate the relations between muscle function and BIVA parameters measured with a standing impedance analyzer in healthy Taiwanese adults. Methods A total of 406 healthy subjects (age 34.5 ± 17.3 years, body mass index 24.1 ± 4.1 kg/m2) were recruited for BIVA and handgrip strength (HGS) measurements. Impedance parameters, including resistance (R) and reactance (Xc), were measured and normalized to body size by dividing by height (H). The resulting phase angle (PhA) was calculated. HGS in the dominant, left, and right hands were referred to as HGSDH, HGSLH, and HGSRH, respectively. All subjects were divided into 5 grades according to HGS. Results Muscle strength in the dominant, right, and left arms was correlated with variables in the order of sex, weight, age, height, Xc/H, and R/H (all, p < 0.001). Using all 6 variables, the determination coefficients were 0.792, 0.782, and 0.745, respectively, whereas the standard errors of estimates were 56.89, 58.01, and 56.67 N for HGSDH, HGSLH, and HGSRH, respectively. HGS was positively correlated with PhA, and negatively correlated with Xc/H and R/H. Conclusions BIVA parameters measured with a standing impedance analyzer and anthropometric variables can predict and discriminate muscle function with good performance in healthy Asian adults.

原文英語
文章編號e0231604
期刊PLoS ONE
卷15
發行號6
DOIs
出版品狀態已出版 - 06 2020

文獻附註

Publisher Copyright:
Copyright: © 2020 Lee et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

指紋

深入研究「Prediction and discrimination of skeletal muscle function by bioelectrical impedance vector analysis using a standing impedance analyzer in healthy Taiwanese adults」主題。共同形成了獨特的指紋。

引用此