Quantitative analysis of system parameters asymmetry on droop-controlled converters

Chia Tse Lee*, Chia Chi Chu, Po Tai Cheng

*此作品的通信作者

研究成果: 圖書/報告稿件的類型會議稿件同行評審

5 引文 斯高帕斯(Scopus)

摘要

In the microgrid applications, the converters come in all sizes and from different manufacturers, thus their closed-loop dynamics and AC side output filters are not going to be the same. The dispersed locations of these converters also lead to unequal power line impedances seen from the converters. These system parameters asymmetry affects the autonomous load sharing operations both in the steady state and in the transient. This paper discusses the impacts of these parameters asymmetry on the dynamics of the entire system. Based on the dynamic model analysis, this paper also provides some existing methods to address these problems.

原文英語
主出版物標題2012 IEEE Energy Conversion Congress and Exposition, ECCE 2012
頁面2381-2388
頁數8
DOIs
出版狀態已出版 - 2012
對外發佈
事件4th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2012 - Raleigh, NC, 美國
持續時間: 15 09 201220 09 2012

出版系列

名字2012 IEEE Energy Conversion Congress and Exposition, ECCE 2012

Conference

Conference4th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2012
國家/地區美國
城市Raleigh, NC
期間15/09/1220/09/12

指紋

深入研究「Quantitative analysis of system parameters asymmetry on droop-controlled converters」主題。共同形成了獨特的指紋。

引用此