TY - JOUR
T1 - Sources and components of volatile organic compounds in breast surgery operating rooms
AU - Cheng, Ming Huei
AU - Chiu, Chun Hui
AU - Chen, Chi Tsung
AU - Chou, Hsu Huan
AU - Pao, Li Heng
AU - Wan, Gwo Hwa
N1 - Publisher Copyright:
© 2020 The Authors
PY - 2021/2
Y1 - 2021/2
N2 - Objectives: The composition and concentration distribution of volatile organic compounds (VOCs) in surgical smoke had seldomly been reported. This study aimed to investigate the profile of VOCs and their concentration in surgical smoke from breast surgery during electrocautery in different tissues, electrosurgical units, and electrocautery powers. Methods: Thirty-eight surgical smoke samples from 23 patients performed breast surgery were collected using evacuated stainless steel canisters. The concentrations of 87 VOCs in surgical smoke samples were analyzed by gas chromatography-mass spectrometry. The human tissues, electrosurgical units, and electrocautery power were recorded. Results: The median level of total VOCs concentrations in surgical smoke samples from mammary glands (total VOCs: 9953.5 ppb; benzene: 222.7 ppb; 1,3-butadiene: 856.2 ppb; vinyl chloride: 3.1 ppb) using conventional electrosurgical knives were significantly higher than that from other tissues (total VOCs: 365.7–4266.8 ppb, P < 0.05; benzene: 26.4–112 ppb, P < 0.05; 1,3-butadiene: 15.6–384 ppb, P < 0.05; vinyl chloride: 0.6–1.8 ppb, P < 0.05) using different electrosurgical units. A high methanol concentration was found in surgical smoke generated during breast surgery (641.4–4452.5 ppb) using different electrosurgical units. An electrocautery power of ≥ 27.5 watts used for skin tissues produced a higher VOCs concentration (2905.8 ppb). Conclusions: The surgical smoke samples collected from mammary glands using conventional electrosurgical knives had high VOCs concentrations. The carcinogens (including benzene, 1,3-butadiene, and vinyl chloride) and methanol were found in the surgical smoke samples from different electrosurgical units. The type of electrosurgical unit and electrocautery power used affected VOCs concentrations in surgical smoke.
AB - Objectives: The composition and concentration distribution of volatile organic compounds (VOCs) in surgical smoke had seldomly been reported. This study aimed to investigate the profile of VOCs and their concentration in surgical smoke from breast surgery during electrocautery in different tissues, electrosurgical units, and electrocautery powers. Methods: Thirty-eight surgical smoke samples from 23 patients performed breast surgery were collected using evacuated stainless steel canisters. The concentrations of 87 VOCs in surgical smoke samples were analyzed by gas chromatography-mass spectrometry. The human tissues, electrosurgical units, and electrocautery power were recorded. Results: The median level of total VOCs concentrations in surgical smoke samples from mammary glands (total VOCs: 9953.5 ppb; benzene: 222.7 ppb; 1,3-butadiene: 856.2 ppb; vinyl chloride: 3.1 ppb) using conventional electrosurgical knives were significantly higher than that from other tissues (total VOCs: 365.7–4266.8 ppb, P < 0.05; benzene: 26.4–112 ppb, P < 0.05; 1,3-butadiene: 15.6–384 ppb, P < 0.05; vinyl chloride: 0.6–1.8 ppb, P < 0.05) using different electrosurgical units. A high methanol concentration was found in surgical smoke generated during breast surgery (641.4–4452.5 ppb) using different electrosurgical units. An electrocautery power of ≥ 27.5 watts used for skin tissues produced a higher VOCs concentration (2905.8 ppb). Conclusions: The surgical smoke samples collected from mammary glands using conventional electrosurgical knives had high VOCs concentrations. The carcinogens (including benzene, 1,3-butadiene, and vinyl chloride) and methanol were found in the surgical smoke samples from different electrosurgical units. The type of electrosurgical unit and electrocautery power used affected VOCs concentrations in surgical smoke.
KW - Breast surgery
KW - Electrocautery power
KW - Electrosurgical units
KW - Surgical smoke
KW - Volatile organic compounds
UR - https://www.scopus.com/pages/publications/85098726493
U2 - 10.1016/j.ecoenv.2020.111855
DO - 10.1016/j.ecoenv.2020.111855
M3 - 文章
C2 - 33385676
AN - SCOPUS:85098726493
SN - 0147-6513
VL - 209
JO - Ecotoxicology and Environmental Safety
JF - Ecotoxicology and Environmental Safety
M1 - 111855
ER -