The influence of over-distraction on biomechanical response of cervical spine post anterior interbody fusion: a comprehensive finite element study

Chih Hsiu Cheng, Ping Yeh Chiu, Hung Bin Chen, Chi Chien Niu*, Mohammad Nikkhoo*

*此作品的通信作者

研究成果: 期刊稿件文章同行評審

1 引文 斯高帕斯(Scopus)

摘要

Introduction: Anterior cervical discectomy and fusion (ACDF) has been considered as the gold standard surgical treatment for cervical degenerative pathologies. Some surgeons tend to use larger-sized interbody cages during ACDF to restore the index intervertebral disc height, hence, this study evaluated the effect of larger-sized interbody cages on the cervical spine with ACDF under both static and cyclic loading. Method: Twenty pre-operative personalized poro-hyperelastic finite element (FE) models were developed. ACDF post-operative models were then constructed and four clinical scenarios (i.e., 1) No-distraction; 2) 1 mm distraction; 3) 2 mm distraction; and 4) 3 mm distraction) were predicted for each patient. The biomechanical responses at adjacent spinal levels were studied subject to static and cyclic loading. Non-parametric Friedman statistical comparative tests were performed and the p values less than 0.05 were reflected as significant. Results: The calculated intersegmental range of motion (ROM) and intradiscal pressure (IDP) from 20 pre-operative FE models were within the overall ranges compared to the available data from literature. Under static loading, greater ROM, IDP, facet joint force (FJF) values were detected post ACDF, as compared with pre-op. Over-distraction induced significantly higher IDP and FJF in both upper and lower adjacent levels in extension. Higher annulus fibrosus stress and strain values, and increased disc height and fluid loss at the adjacent levels were observed in ACDF group which significantly increased for over-distraction groups. Discussion: it was concluded that using larger-sized interbody cages (the height of ≥2 mm of the index disc height) can result in remarkable variations in biomechanical responses of adjacent levels, which may indicate as risk factor for adjacent segment disease. The results of this comprehensive FE investigation using personalized modeling technique highlight the importance of selecting the appropriate height of interbody cage in ACDF surgery.

原文英語
文章編號1217274
期刊Frontiers in Bioengineering and Biotechnology
11
DOIs
出版狀態已出版 - 2023

文獻附註

Publisher Copyright:
Copyright © 2023 Cheng, Chiu, Chen, Niu and Nikkhoo.

指紋

深入研究「The influence of over-distraction on biomechanical response of cervical spine post anterior interbody fusion: a comprehensive finite element study」主題。共同形成了獨特的指紋。

引用此