The Radiation Dose to the Left Supraclavicular Fossa is Critical for Anastomotic Leak Following Esophagectomy – A Dosimetric Outcome Analysis

  • Shang Yu Chou
  • , Hung I. Lu
  • , Yen Hao Chen
  • , Chien Ming Lo
  • , Yun Hsuan Lin
  • , Tzu Ting Huang
  • , Fu Min Fang
  • , Li Chun Chen
  • , Yu Chen
  • , Yi Chun Chiu
  • , Yeh Pin Chou
  • , Shau Hsuan Li*
  • , Yu Ming Wang*
  • *此作品的通信作者
  • Chang Gung University

研究成果: 期刊稿件 › 文章 › 同行評審

1 引文 斯高帕斯(Scopus)

摘要

Purpose: For locally advanced esophageal cancer, definitive concurrent chemoradiotherapy (CCRT) with a radiation dose of 50–50.4 Gy/25-28 Fx is prescribed, followed by adjuvant esophagectomy for better local control or salvage treatment if locoregional recurrence occurs. However, radiation injury before surgery may delay wound healing. We performed cervical anastomosis directly inside the left supraclavicular fossa (SCF), the irradiation target for esophageal cancer. The significance of radiation injury in patients with cervical anastomotic leak (AL) remains unclear. Thus, we assessed the influence of radiation on cervical AL in patients undergoing preoperative CCRT followed by esophagectomy. Patients and Methods: We defined the SYC zone, a portion of the region overlapping the left SCF. The radiation dose to the SYC zone was analyzed and correlated with AL in patients with locally advanced esophageal squamous cell carcinoma (ESCC) who were administered preoperative CCRT (radiation dose with 50–50.4 Gy/25-28 Fx to the primary esophageal tumor) followed by esopha-gectomy between October 2009 and January 2018. Receiver operating characteristic curve analysis and logistic regression were used to identify the optimal radiation factor to predict AL and the cutoff value. Results: The optimal radiation factor to predict AL was the mean dose to the SYC zone (area under the curve (AUC)=0.642), and the cutoff point of the mean dose was 48.55 Gray (Gy). For a mean SYC zone dose ≥48.55 Gy, the AL risk was sevenfold greater than that for <48.55 Gy (OR = 7.805; 95% CI: 1.184 to 51.446; P value = 0.033). Conclusion: Recognizing the SYC zone as an organ at risk and performing radiation evaluation are meaningful. A reduced mean dose of the SYC zone below 48.55 Gy results in a lower cervical AL rate following esophagectomy.

原文英語
頁(從 - 到)1603-1613
頁數11
期刊Cancer Management and Research
卷14
DOIs
出版狀態已出版 - 2022

文獻附註

Publisher Copyright:
© 2022 Chou et al.

UN SDG

此研究成果有助於以下永續發展目標

  1. SDG3 健康與福祉
    SDG3 健康與福祉

指紋

深入研究「The Radiation Dose to the Left Supraclavicular Fossa is Critical for Anastomotic Leak Following Esophagectomy – A Dosimetric Outcome Analysis」主題。共同形成了獨特的指紋。

引用此