The simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid using graphene/size-selected Pt nanocomposites

Chia Liang Sun*, Hsin Hsien Lee, Jen Ming Yang, Ching Chou Wu

*此作品的通信作者

研究成果: 期刊稿件文章同行評審

506 引文 斯高帕斯(Scopus)

摘要

In this study, a graphene/Pt-modified glassy carbon (GC) electrode was created to simultaneously characterize ascorbic acid (AA), dopamine (DA), and uric acid (UA) levels via cyclic voltammetry (CV) and differential pulse voltammetry (DPV). During the preparation of the nanocomposite, size-selected Pt nanoparticles with a mean diameter of 1.7. nm were self-assembled onto the graphene surface. In the simultaneous detection of the three aforementioned analytes using CV, the electrochemical potential differences among the three detected peaks were 185. mV (AA to DA), 144. mV (DA to UA), and 329. mV (AA and UA), respectively. In comparison to the CV results of bare GC and graphene-modified GC electrodes, the large electrochemical potential difference that is achieved via the use of the graphene/Pt nanocomposites is essential to the distinguishing of these three analytes. An optimized adsorption of size-selected Pt colloidal nanoparticles onto the graphene surface results in a graphene/Pt nanocomposite that can provide a good platform for the routine analysis of AA, DA, and UA.

原文英語
頁(從 - 到)3450-3455
頁數6
期刊Biosensors and Bioelectronics
26
發行號8
DOIs
出版狀態已出版 - 15 04 2011

指紋

深入研究「The simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid using graphene/size-selected Pt nanocomposites」主題。共同形成了獨特的指紋。

引用此