Three-dimensional computer-assisted orthognathic surgery: Experience of 37 patients

  • Hsiu Hsia Lin
  • , Hsin Wen Chang
  • , Chien Hsuan Wang
  • , Sun Goo Kim
  • , Lun Jou Lo*
  • *此作品的通信作者
  • Chang Gung Memorial Hospital

研究成果: 期刊稿件文章同行評審

56 引文 斯高帕斯(Scopus)

摘要

Purpose: Three-dimensional computer-assisted orthognathic surgery has been applied to improve planning and outcome. This study presents our experience with this promisingmodality for simulation of surgery, prefabrication of positioning guides, and navigation of the surgery. Methods: Thirty-seven patients who received surgical simulation and intraoperative navigation for 2-jaw orthognathic surgery were recruited. Preoperative 3-dimensional cone-beam computed tomographic images were used for surgical simulation and design of intraoperative guidance. An initial surgical plan was developed and transferred for 3-dimensional virtual surgery. Modification of the surgical plan was made if facial symmetry and skeletal harmony or collision of ramus segments were concerned. The result of virtual surgery was used to design and manufacture positioning guides and perform preoperative navigation planning. During the operation, the positioning guideswere used to transfer the virtual planning to actual surgery, and a real-time navigation systemwas used to confirm the predetermined position of the maxillomandibular complex. For assessment of the computer-assisted surgical system, the simulation imagewas superimposed to the postoperative image for comparison. Results: The computer-assisted orthognathic surgery was successfully carried out in all patients. The initial surgical plan was modified in 17 patients in whom the position of maxillomandibular complex was changed. The positioning guides were helpful in controlling the spatial position of the maxillomandibular complex. The BrainLabTR navigation system was useful to further confirm the position of the facial bone. Superimposition of the simulation and postoperative images revealed satisfactory result with acceptable errors. The difference ranged from 0.05 to 1.46 mm, with a mean value of 0.66 mm, for patients using the positioning guides; and the difference ranged from 0.07 to 2.30 mm, with a mean value of 1.20 mm, for patients using the navigation system. Overall, patient and doctor satisfaction was high. Conclusion: This computer-assisted orthognathic surgery system helps to improve surgical planning, reduce surgical difficulty, facilitate positioning and fixation of the maxillomandibular complex, and improve outcome.

原文英語
頁(從 - 到)S118-S126
期刊Annals of Plastic Surgery
74
DOIs
出版狀態已出版 - 05 2015

文獻附註

Publisher Copyright:
Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.

指紋

深入研究「Three-dimensional computer-assisted orthognathic surgery: Experience of 37 patients」主題。共同形成了獨特的指紋。

引用此