TU‐C‐I‐609‐03: Effects of Exposure and Structural Background On the Detection of Computer‐Simulated Nodules in Digital Chest Phantom Images: 2‐AFC Study

  • C. Lai
  • , C. Shaw
  • , B. Sabloff
  • , T. Wang
  • , X. Liu
  • , L. Chen
  • , Y. Meng
  • , S. Tu
  • , M. Altunbas
  • , S. Kappadath
  • University of Texas MD Anderson Cancer Center

研究成果: 期刊稿件文章同行評審

摘要

Purpose: To investigate how the exposure level and structural background affect the detection of computer‐simulated nodules in digital chest phantom images. Method and Materials: Images of an anthropomorphic chest phantom were acquired with an a‐Si/CsI flat‐panel based digital radiography system at 120 kVp and a tube current ranging from 0.25 to 32 mAs. The source‐to‐image distance (SID) was increased and the x‐ray beam filtered to further reduce the exposure levels. 1‐cm diameter computer‐simulated nodules with a contrast ratio of 2.68% were computer generated at various locations of the chest images. Two‐alternate forced choice (2‐AFC) experiments were performed to measure the ratio of correct observations as a function of the exposure level for various structural backgrounds present. For each exposure level and location, 30 pairs of 512×512 images were generated and displayed in pairs on a review workstation for reading. The ratio of correct observations versus exposure levels were computed from the reading scores for various locations. The plots along with the exposures corresponding to 90% accuracy were used to study the effects of structural backgrounds. Results: For all regions, the accuracy generally increases from 0.5 to 1.0 with the exposure. However, the threshold exposure for 90% accuracy varies with the location. In the abdomen region, the ratio of correct observations reaches 90% at a higher exposure level (∼ 0.4 mAs). In the lung region, the ratio reaches 90% at a much lower exposure level (∼ 0.0625 mAs). The difference in the threshold exposures may be due to the heavier attenuation in the abdomen region. Complexity of structural backgrounds may affect the threshold exposure and the level and consistency of the ratios measured. This work was supported in part by a research grant EB000117 from the NIBIB and a research grant CA104759 from the NCI.

原文英語
頁(從 - 到)2079
頁數1
期刊Medical Physics
32
發行號6
DOIs
出版狀態已出版 - 06 2005
對外發佈

指紋

深入研究「TU‐C‐I‐609‐03: Effects of Exposure and Structural Background On the Detection of Computer‐Simulated Nodules in Digital Chest Phantom Images: 2‐AFC Study」主題。共同形成了獨特的指紋。

引用此