Use of the VIP-man model to calculate energy imparted and effective dose for x-ray examinations

  • Mark Winslow
  • , Walter Huda
  • , X. George Xu*
  • , T. C. Chao
  • , C. Y. Shi
  • , Kent M. Ogden
  • , Ernest M. Scalzetti
  • *此作品的通信作者
  • Rensselaer Polytechnic Institute
  • SUNY Upstate Medical University

研究成果: 期刊稿件文章同行評審

23 引文 斯高帕斯(Scopus)

摘要

A male human tomographic model was used to calculate values of energy imparted (ε) and effective dose (E) for monoenergetic photons (30-150 keV) in radiographic examinations. Energy deposition in the organs and tissues of the human phantom were obtained using Monte Carlo simulations. Values of E/ε were obtained for three common projections [anterior-posterior (AP), posterior-anterior (PA), and lateral (LAT)] of the head, cervical spine, chest, and abdomen, respectively. For head radiographs, all three projections yielded similar E/ε values. At 30 keV, the value of E/ε was ∼1.6 mSv J-1, which is increased to ∼7 mSv J-1 for 150 keV photons. The AP cervical spine was the only projection investigated where the value of E/ε decreased with increasing photon energy. Above 70 keV, cervical spine E/ε values showed little energy dependence and ranged between ∼8.5 mSv J-1 for PA projections and ∼17 mSv J -1 for AP projections. The values of E/ε for AP chest examinations showed very little variation with photon energy, and had values of ∼23 mSv J-1. Values of E/ε for PA and LAT chest projections were substantially lower than the AP projections and increased with increasing photon energy. For abdominal radiographs, differences between the PA and LAT projections were very small. All abdomen projections showed an increase in the E/ε ratio with increasing photon energy, and reached a maximum value of ∼13.5 mSv J-1 for AP projections, and ∼9.5 mSv J -1 for PA/lateral projections. These monoenergetic E/ε values can generate values of E/ε for any x-ray spectrum, and can be used to convert values of energy imparted into effective dose for patients undergoing common head and body radiological examinations.

原文英語
頁(從 - 到)174-182
頁數9
期刊Health Physics
86
發行號2
DOIs
出版狀態已出版 - 02 2004
對外發佈

指紋

深入研究「Use of the VIP-man model to calculate energy imparted and effective dose for x-ray examinations」主題。共同形成了獨特的指紋。

引用此